HVAC, AIR HANDLING EQUIPMENT
KTE-1000AHU
Equipment Introduction
-
Blower airflow, current change experiment by system static pressure change
-
Indoor temperature and humidity change and filter, coil pressure loss practice by blower airflow change
-
Heating, humidification experiment
-
Humid-air chart automatic construction and materials analysis
-
DAQ program supply tools with that temperature, humidity (RH, AH), enthalpy, amount of the exchanged heat in each position can be measured in real time, and then saved by Microsoft Excel, so that saved data can be show and analysis by graph
Equipment Characteristics
-
Cycle composition :
-
Fresh air → mixed air → filter 1 → pre heater → pre cooler → humidifier → filter 2 → re heater → re cooler → blower → room → return air
-
Being practicable to operate on manual, temperature and humidity control with connecting by sequence and drawing a psychometric chart, displaying by digital sign data of temperature and pressure
-
Saving of data in every sec by excel file on PC
-
Experiment factors
-
- Cooling & heating capacity of room chamber
- Bypass factor
- Humidification
- Dehumidification
- Psychrometic chart
- Temperature data
- Being saved on every minute until 1,440 min as excel file after click the “SAVE”
Education Contents
-
Psychrometric Chart drawing using software
-
Measurement analysis pre-cooling and re-cooling of Air handling system
-
Measurement analysis heating and humidification of Air handling system
-
Configuration temperature control sequence circuit for mixture and heating between RA and OA of air handling system and operation
-
Configuration temperature control sequence circuit for mixture and cooling between RA and OA of air handling system and operation
-
Configuration temperature control sequence circuit for mixture and humidification between OA and RA of air handling system and operation
-
Configuration reheating sequence circuit for mixture and preheating, cleaning between OA and RA of air handling system and operation
-
Configuration sequence circuit for pre-cooling of OA and mixture of RA and then cleaning and heating of air handling system and operation
-
Configuration sequence circuit for pre-cooling of OA and mixture of RA and then re-cooling of air handling system and operation
System Description
Air Duct Component
Control Panel Device Component
Mechanical Refrigeration Device Component
Dual Pressure Switch
Structure of DA 100 (Data acquisition) Program
◈Composition of main user interface ◈
(1) Schematic diagram of system show temp, press, in realtime.
(2) Psychometric chart
(3) Data table of temp, humidity, and enthalpy.
(4) Calculation value of performance(BF,CF,q,x)in HX.
◈ Big data auto-storage◈
Video Clips for Product Usage